specification
Specification of AE-600
| Wavelength range |
| 340-999nm |
| Diffraction grating |
| 1200/mm |
| Spectral bandwidth |
| 8nm |
| Wavelength setting |
| Automatic |
| Wavelength setting accuracy |
| 1nm less |
| Cut filter setting |
| Automatic |
| Measurement mode |
| Abs, Kinetic, Fixed Time Kinetic End-Point Plasma-Coagulation (PT,PTT,etc) ※1 |
| Cell |
| Micro Flow Cell |
| Measurement temperature |
| Room temprature, 25℃, 30℃,37℃ |
| Sample volume |
| More than 350µℓ ※2 |
| Photometric accuracy |
| 1% at 1Abs |
| Absorbance range |
| 2.5Abs |
| Stability |
| 0.003Abs/hour |
| Display |
| LCD |
| Printer |
| Thermal dot |
| Interface |
| RS-232C |
| Power supply |
| 100/220V±10% |
| Dimentions |
| 370mm(W)×340mm(D)×190mm(H) |
| Weight |
| 8kg |
- ※1.A sample holder for test tubes as option is necessary in case of plasma-coagulation test.
- ※2.Though it is no problem to measure sample which has more than 350µℓ, better to try to increase total volume of sample suction if density difference between samples is big, or a sample itself has much viscosity.
AE-600の仕様
| 測定波長範囲 |
| 340-999nm |
| 回折格子 |
| 1200/mm |
| 波長幅 |
| 8nm |
| 波長設定 |
| 自動設定 |
| 波長設定精度 |
| 1nm以下 |
| 二次光カットフィルター |
| 自動設定 |
| 測定モード |
| Abs, Kinetic, Fixed Time Kinetic End-Point Plasma-Coagulation(PT,PTT,etc)※1 |
| 試料槽 |
| Micro Flow Cell |
| 測定温度 |
| Room temprature, 25℃, 30℃,37℃ |
| サンプル量 |
| 350µℓ以上 ※2 |
| 光学精度 |
| 1% at 1Abs |
| 吸光度範囲 |
| 2.5Abs |
| 安定性 |
| 0.003Abs/hour |
| 表示 |
| LCD |
| プリンタ |
| 感熱式 |
| インターフェイス |
| RS-232C |
| 電源 |
| 100/220V±10% |
| 寸法 |
| 370mm(W)×340mm(D)×190mm(H) |
| 重量 |
| 8kg |
- ※1.Plasma-Coagulationの測定をする場合は、別途試験管用試料槽が必要です。
- ※2.サンプル総量は350µℓ以上あれば測定可能ですが、測定サンプル間の濃度差が大きかったり、測定サンプルの粘性が高い場合はサンプル吸引量を増やして下さい。
▲ Top of page
accessories
accessories of AE-600
| Standard Accessories | Amount |
| Tungsten lamp(12V 21W) | 2 |
| Fuse(1A) | 2 |
| Power code | 1 |
| Waste liquid bottle with cap & tube |
1 |
| Roller pump tube | 1 |
| Cleaning solution(250ml) | 1 |
| Thermal printing paper(58mmx25M) |
1 |
| Operation Manual | 1 |
option parts of AE-600
| Option |
| TEST TUBE HOLDER |
| PREHEATER |
- *Test tubes 5pcs within 13mm(outer dia.)
- *Reagent Bottles 2pcs Within 25mm(outer dia.)
- *Pipette tips 8pcs
AE-600の付属品
| 標準付属品 | 数量 |
| 光源ランプ(12V 21W) | 2 |
| フューズ(1A) | 1 |
| 電源コード | 1 |
| 廃液瓶セット | 1 |
| ローラーポンプチューブ | 1 |
| 洗浄液(250ml) | 1 |
| プリント紙 | 1 |
| 取り扱い説明書 | 1 |
AE-600のオプション
| オプション |
| 試験管用試料槽 |
| 予備加温器 |
▲ Top of page
Specifications subject to change without notice.